Commit Graph
16 Commits
Author SHA1 Message Date
Claude 7067b53e09 docs: fix apt repo setup for Proxmox 9 (trixie)
PVE9 uses .sources (DEB822 format) not .list files for enterprise repos.
Update distro codename from bookworm to trixie, add ceph-squid
no-subscription repo, and disable both .sources and .list variants
to cover all cases.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-27 03:39:23 +00:00
Claude c2ca356088 docs: fix Phase 3 BIOS table for newer R730xd firmware
VT for Direct I/O toggle and Hard Disk Drive Sequencing were removed
from BIOS 2.19+; VT-d is enabled by default. Add dmesg verification
step and clarify C-states should be disabled. Remove outdated note
pointing users to a nonexistent menu option.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-27 01:46:53 +00:00
Claude 40fe95dec2 docs: update Phase 3 BIOS paths for firmware 2.19.0
Dell R730xd BIOS 2.19.0 renamed settings and reorganized menus:
- "VT for Direct I/O" → "Virtualization Technology for Direct I/O" (same page, scroll down)
- "Power Management" top-level category → "System Profile Settings"
- "Power Management Policy: Performance" → set System Profile to Custom, then CPU Power Management to Maximum Performance
- Add inline note so future readers know why the labels differ from older docs

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-27 01:14:00 +00:00
Claude deb7dc6d48 Complete phases 11-12 walkthrough and add single-document combined guide
Writes the missing Phase 11 (VM creation via Proxmox UI, GPU/Coral/disk
passthrough, Ubuntu install) and Phase 12 (NVIDIA driver, Docker, NVIDIA
Container Toolkit, ZFS pool, Frigate deploy) sections in the existing
walkthrough-phases-10-12.md, then assembles all 12 phases into a single
docs/complete-walkthrough.md with a table of contents and an expanded
troubleshooting section covering guest nvidia-smi failures and ZFS disk-full.

https://claude.ai/code/session_01Mfn4vyaz7wkaDKX7E1VnWc
2026-05-22 18:05:52 +00:00
Claude 16ad3abe2a Add Phase 10 walkthrough: fan control and stagger spin-up services
Covers installing fan-control.sh + systemd service (replacing iDRAC's
100% fan response to non-Dell GPUs), configuring iDRAC BIOS hard disk
drive sequencing via racadm, and the Linux-layer stagger-spinup service
as a safety net. Phases 11 and 12 stubbed as placeholders.

https://claude.ai/code/session_01U7bSqj83VPbMZ9L8LTYa41
2026-04-24 21:40:07 +00:00
Claude 677a85e908 Add session hand-off document
Summarises hardware, all repo files and their status, what still needs
to be written (walkthrough-phases-10-12.md and complete-walkthrough.md),
detailed notes on what phases 10-12 should cover, and key facts/gotchas
for whoever picks this up next.

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 20:46:23 +00:00
Claude 45a14483ca Add detailed button-by-button walkthrough for phases 7-9
Phase 7 — H730 non-RAID conversion:
- perccli download with direct Dell URL and manual fallback
- Script output explained column by column (EID:Slt, State, Size)
- What JBOD vs UGood vs Onln states mean
- Post-reboot verification with lsblk

Phase 8 — Bay mapping:
- build-bay-map.sh output walkthrough
- Physical LED blink procedure (ledctl locate/locate_off per drive)
- Bay numbering convention on R730xd front panel
- How to fill in hardware-layout.md and VM config placeholders

Phase 9 — GPU passthrough:
- Pre-check: dmesg IOMMU confirmation, IOMMU group inspection
- Script output walkthrough step by step
- PCI address capture and immediate VM config update
- Post-reboot verification (must show vfio-pci not nouveau)
- Troubleshooting if wrong driver appears

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 14:48:14 +00:00
Claude 376a328ac4 Correct iDRAC section: server has Express not Enterprise
- Clarify iDRAC8 Express vs Enterprise with explicit feature table
- Remove incorrect claims (virtual console, virtual media) that require Enterprise
- Note physical monitor + keyboard required through Phase 5 (no remote KVM on Express)
- Confirm IPMI over LAN and racadm are available on Express (fan control and
  stagger spinup scripts both work)
- Update "what you need" list to correctly state monitor is required until Phase 6

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 09:50:33 +00:00
Claude cfa323e9af Add detailed button-by-button walkthrough for phases 4-6
Phase 4 — H730 RAID configuration:
- Lifecycle Controller navigation to RAID Configuration
- Identifying 2.5" OS drives vs 3.5" data drives by size
- Clearing foreign configurations if drives have prior RAID history
- Full VD creation wizard with every screen described
- Fast Initialize and verification

Phase 5 — Proxmox install:
- ISO download from proxmox.com
- USB creation for Windows (Rufus, DD mode), Mac (Etcher), Linux (dd)
- F11 UEFI boot menu navigation
- Every installer screen with what to type/select
- Certificate warning walkthrough, subscription nag explained

Phase 6 — Post-install:
- SSH connection
- Repo fix (enterprise → no-subscription community)
- apt dist-upgrade
- Tool installation with explanation of what each does
- Repo clone to /opt/local_proxmox

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 09:47:51 +00:00
Claude 7bd7b8019d Add detailed button-by-button walkthrough for phases 1-3
Covers:
- What iDRAC is in plain English, and why no subscription is needed
- Phase 1: Firmware updates via Lifecycle Controller (F10), including
  how to find the Service Tag and download firmware from Dell's site
  if the server has no internet access
- Phase 2: iDRAC static IP, dedicated NIC port, IPMI over LAN enable,
  default password change, browser login walkthrough
- Phase 3: Every required BIOS setting with exact menu paths —
  VT-x, VT-d, SR-IOV, UEFI boot mode, HDD sequencing, C States

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 09:41:00 +00:00
Claude d04a998d86 Add end-to-end setup guide (bare metal → running Frigate)
12-phase walkthrough covering:
- Firmware updates via Lifecycle Controller
- iDRAC + IPMI over LAN setup (required for fan control)
- BIOS settings checklist (VT-x, VT-d, UEFI mode)
- H730 RAID1 config for 2.5" OS drives, leaving 3.5" for non-RAID
- Proxmox VE 9.1 install and post-install (repo fix, tools, git clone)
- Script run order: perc-nonraid → bay-map → gpu-passthrough → fan/spinup
- VM creation and Frigate Docker+NVIDIA deployment
- Troubleshooting section for common passthrough failures

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 01:18:01 +00:00
Claude 273d6191bd Add VM config examples and Frigate NVR setup
vm-configs/:
- 100-frigate.conf.example: Frigate VM with Quadro P2200 #1, Coral USB, bays 1-8
- 101.conf.example: GPU VM with Quadro P2200 #2, bays 9-10
- 102.conf.example: Utility VM, bays 11-12

frigate/:
- docker-compose.yml: nvidia runtime + Coral USB passthrough, healthcheck
- config.yml: NVDEC hwaccel (preset-nvidia-h264), Coral USB detector,
  motion-based recording retain, per-object score thresholds

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 01:07:21 +00:00
Claude c0604be087 Mark perc-nonraid.sh as executable
https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 01:04:21 +00:00
Claude 889c38c143 Add staggered drive spin-up script and systemd unit
12x 3.5" HDDs spinning up simultaneously can spike ~240W, pushing a single
750W PSU close to its limit. Two-layer fix:
- Layer 1: racadm iDRAC BIOS setting (HddSeq) fires at POST before OS loads
- Layer 2: stagger-spinup.service wakes drives one at a time via hdparm on boot

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 01:04:02 +00:00
Claude ff0711b927 Add GPU passthrough, fan control, and bay mapping scripts
- scripts/build-bay-map.sh: maps physical drive bays to /dev/disk/by-id paths
- scripts/gpu-passthrough-setup.sh: configures IOMMU + vfio-pci for two Quadro P2200s
- scripts/fan-control.sh: ipmitool daemon to prevent iDRAC from running fans at
  100% due to non-Dell PCIe cards; adjusts speed by inlet temperature
- scripts/fan-control.service: systemd unit for fan-control.sh

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 01:00:26 +00:00
Claude 017181c50a Add hardware layout docs and PERC H730 non-RAID setup script
Initial structure for R730xd passthrough configuration:
- README with VM layout table and setup order
- docs/hardware-layout.md: bay/GPU/USB mapping worksheet
- scripts/perc-nonraid.sh: convert H730 drives to per-disk non-RAID mode

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 00:56:05 +00:00