Claude 889c38c143 Add staggered drive spin-up script and systemd unit
12x 3.5" HDDs spinning up simultaneously can spike ~240W, pushing a single
750W PSU close to its limit. Two-layer fix:
- Layer 1: racadm iDRAC BIOS setting (HddSeq) fires at POST before OS loads
- Layer 2: stagger-spinup.service wakes drives one at a time via hdparm on boot

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 01:04:02 +00:00

local_proxmox

Proxmox VE 9.1 configuration, scripts, and VM layouts for a Dell R730xd homelab.

Hardware

  • Host: Dell PowerEdge R730xd
  • RAID controller: PERC H730 (configured in Non-RAID/per-disk passthrough mode)
  • GPUs: 2x Quadro P3300 4GB (VFIO passthrough, one per VM)
  • TPU: Google Coral USB (Frigate object detection)
  • Bays: 12x (not all populated)

VM Layout

VM ID Role Drives GPU Coral
100 Frigate NVR Bays 18 Quadro #1 (VFIO) Yes
101 TBD Bays 910 Quadro #2 (VFIO) No
102 TBD Bays 1112 None No

Setup Order

  1. scripts/perc-nonraid.sh — convert H730 to per-disk non-RAID mode
  2. scripts/build-bay-map.sh — map physical bays to stable /dev/disk/by-id paths
  3. scripts/gpu-passthrough-setup.sh — configure IOMMU + VFIO for both Quadros
  4. Apply VM configs from vm-configs/
  5. Deploy Frigate from frigate/

Docs

S
Description
Mirror of outis1one/local_proxmox from GitHub
Readme
191 KiB
Languages
Shell 100%