Add hardware layout docs and PERC H730 non-RAID setup script
Initial structure for R730xd passthrough configuration: - README with VM layout table and setup order - docs/hardware-layout.md: bay/GPU/USB mapping worksheet - scripts/perc-nonraid.sh: convert H730 drives to per-disk non-RAID mode https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
This commit is contained in:
@@ -1 +1,31 @@
|
||||
# local_proxmox
|
||||
# local_proxmox
|
||||
|
||||
Proxmox VE 9.1 configuration, scripts, and VM layouts for a Dell R730xd homelab.
|
||||
|
||||
## Hardware
|
||||
|
||||
- **Host:** Dell PowerEdge R730xd
|
||||
- **RAID controller:** PERC H730 (configured in Non-RAID/per-disk passthrough mode)
|
||||
- **GPUs:** 2x Quadro P3300 4GB (VFIO passthrough, one per VM)
|
||||
- **TPU:** Google Coral USB (Frigate object detection)
|
||||
- **Bays:** 12x (not all populated)
|
||||
|
||||
## VM Layout
|
||||
|
||||
| VM ID | Role | Drives | GPU | Coral |
|
||||
|-------|------|--------|-----|-------|
|
||||
| 100 | Frigate NVR | Bays 1–8 | Quadro #1 (VFIO) | Yes |
|
||||
| 101 | TBD | Bays 9–10 | Quadro #2 (VFIO) | No |
|
||||
| 102 | TBD | Bays 11–12 | None | No |
|
||||
|
||||
## Setup Order
|
||||
|
||||
1. [`scripts/perc-nonraid.sh`](scripts/perc-nonraid.sh) — convert H730 to per-disk non-RAID mode
|
||||
2. [`scripts/build-bay-map.sh`](scripts/build-bay-map.sh) — map physical bays to stable `/dev/disk/by-id` paths
|
||||
3. [`scripts/gpu-passthrough-setup.sh`](scripts/gpu-passthrough-setup.sh) — configure IOMMU + VFIO for both Quadros
|
||||
4. Apply VM configs from [`vm-configs/`](vm-configs/)
|
||||
5. Deploy Frigate from [`frigate/`](frigate/)
|
||||
|
||||
## Docs
|
||||
|
||||
- [`docs/hardware-layout.md`](docs/hardware-layout.md) — bay/device/VM mapping worksheet
|
||||
|
||||
@@ -0,0 +1,65 @@
|
||||
# Hardware Layout
|
||||
|
||||
Dell R730xd — fill this in after running `scripts/build-bay-map.sh`.
|
||||
|
||||
## Bay → Device → VM Map
|
||||
|
||||
Run `scripts/build-bay-map.sh` on the Proxmox host to auto-populate the by-id column.
|
||||
Confirm bay numbers by running `ledctl locate=<device>` to blink the drive LED.
|
||||
|
||||
| Bay | Assigned VM | Size | /dev/disk/by-id (fill in) | Notes |
|
||||
|-----|-------------|------|---------------------------|-------|
|
||||
| 1 | 100 | | | |
|
||||
| 2 | 100 | | | |
|
||||
| 3 | 100 | | | |
|
||||
| 4 | 100 | | | |
|
||||
| 5 | 100 | | | |
|
||||
| 6 | 100 | | | |
|
||||
| 7 | 100 | | | |
|
||||
| 8 | 100 | | | |
|
||||
| 9 | 101 | | | |
|
||||
| 10 | 101 | | | |
|
||||
| 11 | 102 | | | |
|
||||
| 12 | 102 | | | |
|
||||
|
||||
## GPU Map
|
||||
|
||||
Run `lspci -nn | grep -i nvidia` on the Proxmox host and fill in the PCI addresses.
|
||||
|
||||
| Slot | PCI Address (fill in) | Assigned VM | Notes |
|
||||
|------|-----------------------|-------------|-------|
|
||||
| GPU 1 | | 100 | Frigate decode + display |
|
||||
| GPU 2 | | 101 | |
|
||||
|
||||
The GPU's HDMI audio function (same address, function 1) must be passed through alongside the GPU.
|
||||
Example: GPU at `01:00.0` → also pass `01:00.1`.
|
||||
|
||||
## USB / TPU Map
|
||||
|
||||
| Device | VID:PID | Assigned VM | Notes |
|
||||
|--------|---------|-------------|-------|
|
||||
| Coral (pre-init) | 1a6e:089a | 100 | Global Unichip — before first inference |
|
||||
| Coral (post-init) | 18d1:9302 | 100 | Google — after first inference; pass both |
|
||||
|
||||
## IOMMU Groups
|
||||
|
||||
Run on Proxmox host to check groupings before passthrough:
|
||||
|
||||
```bash
|
||||
for d in /sys/kernel/iommu_groups/*/devices/*; do
|
||||
n=${d#*/iommu_groups/*}; n=${n%%/*}
|
||||
printf 'IOMMU Group %s ' "$n"
|
||||
lspci -nns "${d##*/}"
|
||||
done | sort -V
|
||||
```
|
||||
|
||||
Each GPU should appear in its own group (with only its HDMI audio sibling).
|
||||
If a GPU shares a group with other devices, those must be passed through together.
|
||||
|
||||
## Network
|
||||
|
||||
| VM | Interface | Bridge | Notes |
|
||||
|-----|-----------|--------|-------|
|
||||
| 100 | net0 | vmbr0 | |
|
||||
| 101 | net0 | vmbr0 | |
|
||||
| 102 | net0 | vmbr0 | |
|
||||
@@ -0,0 +1,53 @@
|
||||
#!/usr/bin/env bash
|
||||
# Convert PERC H730 drives to Non-RAID (per-disk passthrough) mode.
|
||||
# Run once on the Proxmox host before assigning drives to VMs.
|
||||
# Requires: perccli (install from Dell's website or local .deb)
|
||||
#
|
||||
# Dell PERC H730 does not have a true HBA/IT mode. Non-RAID mode is the
|
||||
# equivalent — each disk is presented directly to the OS with SMART intact.
|
||||
|
||||
set -euo pipefail
|
||||
|
||||
PERCCLI=$(command -v perccli || command -v perccli64 || true)
|
||||
if [[ -z "$PERCCLI" ]]; then
|
||||
echo "perccli not found. Install from:"
|
||||
echo " https://www.dell.com/support (search 'PERCCLI')"
|
||||
echo " or: dpkg -i perccli_*.deb"
|
||||
exit 1
|
||||
fi
|
||||
|
||||
echo "=== Controller overview ==="
|
||||
$PERCCLI show
|
||||
|
||||
echo ""
|
||||
echo "=== Drives on controller 0 ==="
|
||||
$PERCCLI /c0 /eall /sall show
|
||||
|
||||
echo ""
|
||||
read -rp "Proceed with converting all non-OS drives to Non-RAID mode? [y/N] " confirm
|
||||
[[ "$confirm" =~ ^[Yy]$ ]] || { echo "Aborted."; exit 0; }
|
||||
|
||||
# Identify enclosure IDs (typically 8 for the internal backplane on R730xd)
|
||||
ENCLOSURES=$($PERCCLI /c0 /eall show | awk '/^[0-9]/{print $1}' | sort -u)
|
||||
|
||||
for enc in $ENCLOSURES; do
|
||||
echo ""
|
||||
echo "=== Processing enclosure $enc ==="
|
||||
SLOTS=$($PERCCLI /c0 /e"$enc" /sall show | awk '/UGood|Onln|JBOD|DHS/{print $2}' | sort -u)
|
||||
|
||||
for slot in $SLOTS; do
|
||||
echo -n " Slot $slot: setting to Good... "
|
||||
$PERCCLI /c0 /e"$enc" /s"$slot" set good force 2>&1 | grep -i "success\|error\|already" || true
|
||||
|
||||
echo -n " Slot $slot: setting to Non-RAID... "
|
||||
$PERCCLI /c0 /e"$enc" /s"$slot" set nonraid 2>&1 | grep -i "success\|error\|already" || true
|
||||
done
|
||||
done
|
||||
|
||||
echo ""
|
||||
echo "=== Final drive state ==="
|
||||
$PERCCLI /c0 /eall /sall show
|
||||
|
||||
echo ""
|
||||
echo "Done. Reboot the host for changes to take full effect."
|
||||
echo "After reboot, run build-bay-map.sh to map bays to /dev/disk/by-id paths."
|
||||
Reference in New Issue