/home/kiosk is mode 700 so root cannot traverse it. Every [[ -f ]] or
[[ ! -f ]] check on paths inside /home/kiosk was silently returning
'not found' even after the kiosk user had successfully written the file.
Replace all three [[ ! -f "$electron_bin" ]] checks and the
[[ -f "$sandbox" ]] check in install_electron_binary with
sudo -u "$KIOSK_USER" test -f so they run in the kiosk user's
security context and can actually see the files.
https://claude.ai/code/session_01VQ13Fwq4MXxwThLfCXBeGr
Accidentally dropped this line when rewriting the extraction block.
mktemp creates the file as root:root 600, so sudo -u kiosk unzip
gets 'Permission denied' trying to open the zipfile.
https://claude.ai/code/session_01VQ13Fwq4MXxwThLfCXBeGr
The previous fix incorrectly ran unzip as root, which fails because
/home/kiosk is not accessible to root. The kiosk user is the right
actor for the extraction, but two things blocked it:
1. node_modules/electron/dist/ can be owned by root when npm's electron
postinstall runs with --unsafe-perm, so the kiosk user gets
'Permission denied' trying to write there. Fix: sudo chown -R the
electron directory to the kiosk user before extracting.
2. With set -euo pipefail active (upgrade call had no || guard), a
failed unzip or chmod would abort the script silently before the
diagnostic error messages could print. Fix: add || true to both
commands so the function always reaches the explicit -f check which
prints the real error and returns 1. The upgrade call already has
|| { log_error ...; return 1; } from the previous commit.
https://claude.ai/code/session_01VQ13Fwq4MXxwThLfCXBeGr
Two bugs combined to cause the 'Electron binary download failed' error
even though the zip downloaded and unzip reported inflating all files:
1. The upgrade path called install_electron_binary bare (no ||), so
set -euo pipefail was active inside the function. Any failing command
(e.g. chmod on a file that wasn't written) killed the script before
the error messages printed. Fresh install used || exit 1, which
disables set -e inside the function body. Upgrade now uses
|| { log_error ...; return 1; } to match.
2. The unzip ran as the kiosk user, but node_modules/electron/dist/ can
be owned by root when npm's electron postinstall script runs with
--unsafe-perm. The kiosk user can't write there, so unzip's write
errors go to stderr (not visible in the log) while inflating: lines
still appear on stdout. The binary is never actually written.
Fix: run mkdir/unzip/chmod as root, then chown -R to kiosk.
https://claude.ai/code/session_01VQ13Fwq4MXxwThLfCXBeGr
mktemp creates the tmp zip owned by root with mode 600.
sudo -u kiosk unzip then fails with "Permission denied".
Add chmod 644 immediately after download so the kiosk user can read it.
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU
When the script is run via curl|bash or wget|bash, BASH_SOURCE[0] is a
pipe descriptor, not a real file. The upgrade function grep-extracts
heredocs from the script file, so it fails with a confusing path error.
Fixes:
- Set SCRIPT_FILE global at startup (empty string when piped)
- upgrade_kiosk() checks SCRIPT_FILE before asking "Continue?" and shows
a clear message explaining how to download the script to a file first
- Removes the silent failure path (no more cryptic "Cannot find script at
/proc/.../pipe:[...]" error)
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU
Fresh Ubuntu 24.04 minimal installs don't include unzip. The wget fallback
in install_electron_binary() downloaded the 120MB Electron zip successfully
but then failed on the unzip call. Two fixes:
1. Add unzip to the main apt install step so it's always present.
2. Auto-install unzip inside install_electron_binary() as a safety net for
upgrades on existing systems that may not have it.
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU
Drop the MatchProduct "Finger" restriction from the xorg libinput rule,
leaving only MatchIsTouchscreen "on". MatchIsTouchscreen is set by udev
from hardware capabilities, so it matches finger touch screens of any
brand (ELAN, Goodix, eGalax, Wacom, etc.) while never matching keyboards,
mice, or pen/stylus digitizers (which are tagged as tablets, not
touchscreens). This makes the script work on any touch hardware without
hardcoding device names. Behavior on existing Wacom machines is unchanged
since their finger device matched either way.
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU
Two genuinely separate root causes were behind the dead touchscreen:
1. GNOME keyring grab — under LightDM autologin the keyring stays locked.
When Chromium accessed it, the gcr-prompter unlock dialog grabbed all
keyboard and touch input at the X level. The app rendered (timers ran)
but ignored every tap and keypress. Fix: --password-store=basic stops
Electron from using the keyring, so the dialog never appears.
2. Wacom driver single-touch emulation — the wacom X driver only does
single-touch pointer emulation and never passes real multitouch to
Chromium, so 1-finger and 2-finger swipe gestures could not fire.
Fix: force the finger touch device to the libinput driver via
/etc/X11/xorg.conf.d/99-finger-libinput.conf. libinput delivers proper
XI2 multitouch which Chromium turns into real JS touch events. The
pen/stylus stays on the wacom driver.
Removed the earlier dead-end attempts (xsetwacom MapToOutput / CTM reset,
Wacom Enable Touch Gesture, 99-wacom-touch.conf) which were all chasing the
wrong cause while the keyring grab masked any real testing. The upgrade path
removes the stale 99-wacom-touch.conf so it can't override libinput.
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU
The Wacom driver owns the Coordinate Transformation Matrix and silently
overrides any xinput set-prop changes. xsetwacom MapToOutput tells the
driver to recalculate the CTM for the primary connected output, which is
the correct API and persists across driver resets.
Dynamically detects the primary output (eDP1, HDMI1, DP1, etc.) so the
fix works on any machine without hardcoding a display name.
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU
The Wacom driver can initialise the CTM to all-zeros, which maps every
touch event to screen coordinate (0,0). The touchscreen appears completely
dead even though the hardware and kernel are working correctly.
Reset the CTM to the identity matrix for every touch/finger device at
startup, before launching Electron, so coordinates are always correct.
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU
xorg uses fnmatch (shell glob) for MatchProduct, where . is a literal
dot. Wacom.*Finger never matched "Wacom HID 48E3 Finger touch" because
there is no literal dot in that string. Wacom*Finger* matches correctly.
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU
Without /etc/X11/xorg.conf.d/99-wacom-touch.conf the Wacom driver initialises
the finger touch device in pointer emulation mode (generating RawButtonPress/
RawButtonRelease/RawMotion). Electron never sees TouchBegin/TouchEnd events so
touchstart/pointerdown(touch) never fire in the renderer.
Setting Option "Gesture" "on" and Option "Touch" "on" at the driver level means
the device initialises in XI2 touch mode on every X server start, regardless of
any post-init xinput set-prop calls.
Added to both fresh install (step 18) and upgrade function.
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU
Without XAUTHORITY set, xinput can fail with "Authorization required"
if the display manager doesn't propagate it through the session environment.
Hardcode the kiosk user's .Xauthority path to guarantee xinput works.
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU
Update all version strings (header, SCRIPT_VERSION, JS VERSION constant)
and rename ubuntu-based-kiosk-v1.0.2.sh → ubuntu-based-kiosk-v1.0.3.sh.
Update README with v1.0.3 change log and archive v1.0.2 as previous.
https://claude.ai/code/session_01EyjEQLWbTXcZgbMDarf7NU