Compare commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
9b339b33f1 | ||
|
|
f687bd4f54 |
@@ -2309,64 +2309,9 @@ Click **Next**.
|
|||||||
|
|
||||||
Click **Next**, then **Finish**.
|
Click **Next**, then **Finish**.
|
||||||
|
|
||||||
VM 100 now appears in the left panel. **Do not start it yet** — the GPU and
|
VM 100 now appears in the left panel. **Do not start it yet** — data drives
|
||||||
data drives must be added first.
|
must be added first (Steps 11.6–11.8). The GPU and USB PCIe card are added
|
||||||
|
**after** the OS is installed (Steps 11.4 and 11.4b, later in this phase).
|
||||||
After the wizard completes, add the GPU in the **Hardware** tab:
|
|
||||||
|
|
||||||
Click **Add** → **PCI Device**.
|
|
||||||
|
|
||||||
| Field | Value |
|
|
||||||
|-------|-------|
|
|
||||||
| Raw Device | select the GPU from the dropdown |
|
|
||||||
| All Functions | **checked** |
|
|
||||||
| ROM-Bar | **checked** |
|
|
||||||
| PCI-Express | **checked** |
|
|
||||||
| Primary GPU | **checked** |
|
|
||||||
|
|
||||||
Click **Add**.
|
|
||||||
|
|
||||||
> **ROM-Bar must stay checked.** NVIDIA drivers read the GPU's VBIOS through
|
|
||||||
> the ROM BAR during initialization. Unchecking it causes the driver to fail
|
|
||||||
> or the GPU to not be recognized inside the VM.
|
|
||||||
|
|
||||||
> VM 100 gets the GPU for Jellyfin transcoding, Immich ML acceleration,
|
|
||||||
> HandBrake encoding, and general desktop GPU acceleration.
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
### Step 11.4b — Add USB 3.0 PCIe card to VM 100
|
|
||||||
|
|
||||||
Still in VM 100's **Hardware** tab. Click **Add** → **PCI Device**.
|
|
||||||
|
|
||||||
First, identify the card's PCI address on the Proxmox host:
|
|
||||||
|
|
||||||
```bash
|
|
||||||
lspci | grep -i usb
|
|
||||||
# Look for the PCIe card — e.g.:
|
|
||||||
# 82:00.0 USB controller: VIA Technologies, Inc. VL805/806 xHCI USB 3.0 Controller (rev 01)
|
|
||||||
```
|
|
||||||
|
|
||||||
In the dialog:
|
|
||||||
|
|
||||||
| Field | Value |
|
|
||||||
|-------|-------|
|
|
||||||
| Raw Device | selected |
|
|
||||||
| Device | 0000:82:00.0 (your address from lspci) |
|
|
||||||
| All Functions | checked |
|
|
||||||
| PCI-Express | checked |
|
|
||||||
| ROM-Bar | checked |
|
|
||||||
| Primary GPU | unchecked |
|
|
||||||
|
|
||||||
Click **Add**.
|
|
||||||
|
|
||||||
All ports on the USB card are now owned by VM 100. The Coral TPU for VM 101
|
|
||||||
(Frigate) uses one of the server's built-in rear USB ports instead — it only
|
|
||||||
needs USB 3.0 speed and works on any port.
|
|
||||||
|
|
||||||
> **VL805/VIA cards** are single-function (one PCI address), so All Functions
|
|
||||||
> has no effect but does no harm. ASMedia and other multi-function cards
|
|
||||||
> benefit from it more.
|
|
||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
@@ -2711,81 +2656,7 @@ Click **Add**.
|
|||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
### Step 11.10 — Create VM 102 (Windows 11, Sync.com)
|
### Step 11.10 — Install Ubuntu Desktop in VM 100
|
||||||
|
|
||||||
VM 102 is a Windows 11 VM that runs the Sync.com desktop client for cloud
|
|
||||||
backup. Syncthing on VM 100 (Services) mirrors NAS data to VM 102's local
|
|
||||||
NTFS drive, and Sync.com picks it up natively.
|
|
||||||
|
|
||||||
Click **Create VM** again.
|
|
||||||
|
|
||||||
**Tab: General**
|
|
||||||
|
|
||||||
| Field | Value |
|
|
||||||
|-------|-------|
|
|
||||||
| VM ID | 102 |
|
|
||||||
| Name | windows-sync |
|
|
||||||
|
|
||||||
**Tab: OS**
|
|
||||||
|
|
||||||
| Field | Value |
|
|
||||||
|-------|-------|
|
|
||||||
| ISO image | windows11 ISO (upload to local storage first) |
|
|
||||||
| OS Type | Microsoft Windows |
|
|
||||||
| Version | 11/2022/2025 |
|
|
||||||
|
|
||||||
**Tab: System**
|
|
||||||
|
|
||||||
| Field | Value |
|
|
||||||
|-------|-------|
|
|
||||||
| Graphic card | Default (VirtIO) |
|
|
||||||
| Machine | q35 |
|
|
||||||
| BIOS | OVMF (UEFI) |
|
|
||||||
| Add EFI Disk | checked |
|
|
||||||
| EFI Storage | local-lvm |
|
|
||||||
| Pre-Enrolled Keys | **checked** (Windows 11 requires Secure Boot) |
|
|
||||||
| Add TPM | **checked**, TPM Storage: local-lvm (Windows 11 requires TPM 2.0) |
|
|
||||||
| SCSI Controller | VirtIO SCSI Single |
|
|
||||||
|
|
||||||
**Tab: Disks**
|
|
||||||
|
|
||||||
| Field | Value |
|
|
||||||
|-------|-------|
|
|
||||||
| Disk size (GiB) | 128 |
|
|
||||||
| Storage | local-lvm |
|
|
||||||
| Cache | Write back |
|
|
||||||
|
|
||||||
**Tab: CPU**
|
|
||||||
|
|
||||||
| Field | Value |
|
|
||||||
|-------|-------|
|
|
||||||
| Sockets | 1 |
|
|
||||||
| Cores | 4 |
|
|
||||||
| Type | host |
|
|
||||||
|
|
||||||
**Tab: Memory**
|
|
||||||
|
|
||||||
| Field | Value |
|
|
||||||
|-------|-------|
|
|
||||||
| Memory (MiB) | 8192 |
|
|
||||||
|
|
||||||
Click **Finish**.
|
|
||||||
|
|
||||||
Then pass a dedicated data drive to VM 102 for Sync.com to sync to:
|
|
||||||
|
|
||||||
```bash
|
|
||||||
# Use one of your spare HDDs — Sync.com data lives here (formatted NTFS in Windows)
|
|
||||||
qm set 102 -scsi1 /dev/disk/by-id/PLACEHOLDER_SYNC_DRIVE
|
|
||||||
```
|
|
||||||
|
|
||||||
> **Why a dedicated drive?** Sync.com needs a real local NTFS disk — not a
|
|
||||||
> network share, not a shared folder. Windows formats this drive NTFS and
|
|
||||||
> Sync.com treats it as a native local drive. Syncthing on VM 100 (Services)
|
|
||||||
> pushes data to it over the LAN.
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
### Step 11.11 — Install Ubuntu Desktop in VM 100
|
|
||||||
|
|
||||||
In the left panel, click **100** → click **Start** (▶ button).
|
In the left panel, click **100** → click **Start** (▶ button).
|
||||||
|
|
||||||
@@ -2819,7 +2690,7 @@ the ISO automatically.
|
|||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
### Step 11.12 — Find VM 100's IP and test SSH
|
### Step 11.11 — Find VM 100's IP and test SSH
|
||||||
|
|
||||||
Log in at the console. Check the assigned IP:
|
Log in at the console. Check the assigned IP:
|
||||||
|
|
||||||
@@ -2847,7 +2718,7 @@ If SSH connects, close the noVNC console tab — you will not need it again.
|
|||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
### Step 11.13 — Disable Wayland, force Xorg
|
### Step 11.12 — Disable Wayland, force Xorg
|
||||||
|
|
||||||
Ubuntu 24.04 defaults to Wayland. WinApps file sharing (`\\tsclient\home`)
|
Ubuntu 24.04 defaults to Wayland. WinApps file sharing (`\\tsclient\home`)
|
||||||
breaks under Wayland due to FreeRDP limitations — tsclient mounts as empty.
|
breaks under Wayland due to FreeRDP limitations — tsclient mounts as empty.
|
||||||
@@ -2878,7 +2749,69 @@ echo $XDG_SESSION_TYPE # should print: x11
|
|||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
### Step 11.14 — Install Ubuntu Server in VM 101
|
### Step 11.13 — Add GPU to VM 100
|
||||||
|
|
||||||
|
Now that Ubuntu is installed and the noVNC console is no longer needed, add
|
||||||
|
the GPU. **Shut down VM 100 first** (`sudo poweroff` inside the VM).
|
||||||
|
|
||||||
|
In VM 100's **Hardware** tab, click **Add** → **PCI Device**.
|
||||||
|
|
||||||
|
| Field | Value |
|
||||||
|
|-------|-------|
|
||||||
|
| Raw Device | select the GPU from the dropdown |
|
||||||
|
| All Functions | **checked** |
|
||||||
|
| ROM-Bar | **checked** |
|
||||||
|
| PCI-Express | **checked** |
|
||||||
|
| Primary GPU | **checked** |
|
||||||
|
|
||||||
|
Click **Add**.
|
||||||
|
|
||||||
|
> **ROM-Bar must stay checked.** NVIDIA drivers read the GPU's VBIOS through
|
||||||
|
> the ROM BAR during initialization. Unchecking it causes the driver to fail
|
||||||
|
> or the GPU to not be recognized inside the VM.
|
||||||
|
|
||||||
|
Also change the Display device: **Hardware → Display → Edit → Graphic card: none**.
|
||||||
|
noVNC will stop working after this — all console access goes through SSH or
|
||||||
|
the GPU's physical output.
|
||||||
|
|
||||||
|
---
|
||||||
|
|
||||||
|
### Step 11.14 — Add USB 3.0 PCIe card to VM 100
|
||||||
|
|
||||||
|
Still in VM 100's **Hardware** tab (VM still shut down). Click **Add** → **PCI Device**.
|
||||||
|
|
||||||
|
First, identify the card's PCI address on the Proxmox host:
|
||||||
|
|
||||||
|
```bash
|
||||||
|
lspci | grep -i usb
|
||||||
|
# Look for the PCIe card — e.g.:
|
||||||
|
# 82:00.0 USB controller: VIA Technologies, Inc. VL805/806 xHCI USB 3.0 Controller (rev 01)
|
||||||
|
```
|
||||||
|
|
||||||
|
In the dialog:
|
||||||
|
|
||||||
|
| Field | Value |
|
||||||
|
|-------|-------|
|
||||||
|
| Raw Device | selected |
|
||||||
|
| Device | 0000:82:00.0 (your address from lspci) |
|
||||||
|
| All Functions | checked |
|
||||||
|
| PCI-Express | checked |
|
||||||
|
| ROM-Bar | checked |
|
||||||
|
| Primary GPU | unchecked |
|
||||||
|
|
||||||
|
Click **Add**, then start VM 100.
|
||||||
|
|
||||||
|
All ports on the USB card are now owned by VM 100. The Coral TPU for VM 101
|
||||||
|
(Frigate) uses one of the server's built-in rear USB ports instead — it only
|
||||||
|
needs USB 3.0 speed and works on any port.
|
||||||
|
|
||||||
|
> **VL805/VIA cards** are single-function (one PCI address), so All Functions
|
||||||
|
> has no effect but does no harm. ASMedia and other multi-function cards
|
||||||
|
> benefit from it more.
|
||||||
|
|
||||||
|
---
|
||||||
|
|
||||||
|
### Step 11.15 — Install Ubuntu Server in VM 101
|
||||||
|
|
||||||
Start VM 101, open the console, and work through the Ubuntu Server installer.
|
Start VM 101, open the console, and work through the Ubuntu Server installer.
|
||||||
Use `frigate` as the hostname. When prompted for storage, install only to the
|
Use `frigate` as the hostname. When prompted for storage, install only to the
|
||||||
@@ -2888,11 +2821,6 @@ when prompted so you can SSH in for Phase 12.
|
|||||||
> **No Wayland to disable** — Ubuntu Server has no desktop environment.
|
> **No Wayland to disable** — Ubuntu Server has no desktop environment.
|
||||||
> After install, SSH in directly: `ssh ubuntu@<vm101-ip>`
|
> After install, SSH in directly: `ssh ubuntu@<vm101-ip>`
|
||||||
|
|
||||||
**VM 102 (Windows 11):** Boot from the Windows 11 ISO, work through the
|
|
||||||
installer. Use `windows-sync` as the hostname. Install to the 128 GiB OS disk.
|
|
||||||
After install, format the dedicated Sync.com data drive as NTFS in Disk
|
|
||||||
Management, then install the Sync.com desktop client and point it at that drive.
|
|
||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
### Phase 11 complete — where you are now
|
### Phase 11 complete — where you are now
|
||||||
@@ -2900,10 +2828,9 @@ Management, then install the Sync.com desktop client and point it at that drive.
|
|||||||
| What is done | Status |
|
| What is done | Status |
|
||||||
|---|---|
|
|---|---|
|
||||||
| Ubuntu Server 24.04.4 and Desktop 24.04.4 ISOs uploaded to Proxmox | ✓ |
|
| Ubuntu Server 24.04.4 and Desktop 24.04.4 ISOs uploaded to Proxmox | ✓ |
|
||||||
| VM 100 created: GPU, 8 raw data drives, services (Immich/Jellyfin/Audiobookshelf/NAS) | ✓ |
|
| VM 100 created: GPU, raw data drives, services (Immich/Jellyfin/Audiobookshelf/NAS) | ✓ |
|
||||||
| VM 101 created: Coral USB (×2), security VLAN, Frigate NVR | ✓ |
|
| VM 101 created: Coral USB, security VLAN, Frigate NVR | ✓ |
|
||||||
| VM 102 created: Windows 11, Sync.com | ✓ |
|
| Ubuntu installed and SSH accessible in both VMs | ✓ |
|
||||||
| Ubuntu installed and SSH accessible in all three VMs | ✓ |
|
|
||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
@@ -3257,7 +3184,6 @@ stats. Navigate to **System → Stats** to confirm:
|
|||||||
| Services | fan-control (quiet fans), stagger-spinup (PSU protection) | ✓ |
|
| Services | fan-control (quiet fans), stagger-spinup (PSU protection) | ✓ |
|
||||||
| VM 100 | Ubuntu Desktop 24.04.4, GPU passthrough, 8 drives, Immich/Jellyfin/Audiobookshelf/NAS | ✓ |
|
| VM 100 | Ubuntu Desktop 24.04.4, GPU passthrough, 8 drives, Immich/Jellyfin/Audiobookshelf/NAS | ✓ |
|
||||||
| VM 101 | Ubuntu Server 24.04.4, Coral TPU, Frigate NVR, security VLAN | ✓ |
|
| VM 101 | Ubuntu Server 24.04.4, Coral TPU, Frigate NVR, security VLAN | ✓ |
|
||||||
| VM 102 | Windows 11, Sync.com | ready |
|
|
||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue