H730 requires two steps: enable JBOD on the controller, then set each
UGood drive to JBOD state. Without both, drives show in perccli but
are invisible to lsblk/the OS. Also skip Onln drives (OS RAID members).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Replace all prose mentions of 'Quadro P2200' with generic GPU language.
Sample command output blocks left as-is (they're illustrative, not prescriptive).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
apt and direct Dell URLs don't work. Working method: curl with referer
header to get the RPM, convert with alien, symlink binary into PATH.
Update both setup-guide and perc-nonraid.sh error message to match.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
The hardcoded dl.dell.com tarball URL is stale and returns a redirect.
Suggest 'apt install perccli' first (available in Proxmox repos), then
fall back to manual .deb download via dell.com/support with service tag.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
BIOS.StorageSettings.HddSeq no longer exists on R730xd firmware 2.19+.
Update --idrac mode to print a clear explanation instead of failing,
and update docs to skip Layer 1 and go straight to the Linux systemd service.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Fall through to /etc/default/grub + update-grub when /etc/kernel/cmdline
doesn't exist, instead of erroring out. Covers systems that booted via
legacy GRUB rather than the Proxmox EFI boot tool.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
12x 3.5" HDDs spinning up simultaneously can spike ~240W, pushing a single
750W PSU close to its limit. Two-layer fix:
- Layer 1: racadm iDRAC BIOS setting (HddSeq) fires at POST before OS loads
- Layer 2: stagger-spinup.service wakes drives one at a time via hdparm on boot
https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
- scripts/build-bay-map.sh: maps physical drive bays to /dev/disk/by-id paths
- scripts/gpu-passthrough-setup.sh: configures IOMMU + vfio-pci for two Quadro P2200s
- scripts/fan-control.sh: ipmitool daemon to prevent iDRAC from running fans at
100% due to non-Dell PCIe cards; adjusts speed by inlet temperature
- scripts/fan-control.service: systemd unit for fan-control.sh
https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
Initial structure for R730xd passthrough configuration:
- README with VM layout table and setup order
- docs/hardware-layout.md: bay/GPU/USB mapping worksheet
- scripts/perc-nonraid.sh: convert H730 drives to per-disk non-RAID mode
https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD