Commit Graph
4 Commits
Author SHA1 Message Date
Claude c0604be087 Mark perc-nonraid.sh as executable
https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 01:04:21 +00:00
Claude 889c38c143 Add staggered drive spin-up script and systemd unit
12x 3.5" HDDs spinning up simultaneously can spike ~240W, pushing a single
750W PSU close to its limit. Two-layer fix:
- Layer 1: racadm iDRAC BIOS setting (HddSeq) fires at POST before OS loads
- Layer 2: stagger-spinup.service wakes drives one at a time via hdparm on boot

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 01:04:02 +00:00
Claude ff0711b927 Add GPU passthrough, fan control, and bay mapping scripts
- scripts/build-bay-map.sh: maps physical drive bays to /dev/disk/by-id paths
- scripts/gpu-passthrough-setup.sh: configures IOMMU + vfio-pci for two Quadro P2200s
- scripts/fan-control.sh: ipmitool daemon to prevent iDRAC from running fans at
  100% due to non-Dell PCIe cards; adjusts speed by inlet temperature
- scripts/fan-control.service: systemd unit for fan-control.sh

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 01:00:26 +00:00
Claude 017181c50a Add hardware layout docs and PERC H730 non-RAID setup script
Initial structure for R730xd passthrough configuration:
- README with VM layout table and setup order
- docs/hardware-layout.md: bay/GPU/USB mapping worksheet
- scripts/perc-nonraid.sh: convert H730 drives to per-disk non-RAID mode

https://claude.ai/code/session_01TxTSnxDjgEVuNztdsWQjMD
2026-04-24 00:56:05 +00:00