# Phases 1–3: Firmware, iDRAC, and BIOS
|
||||
### Dell R730xd — Button-by-button walkthrough
|
||||
|
||||
---
|
||||
|
||||
## Before You Touch Anything — Read This First
|
||||
|
||||
### What is iDRAC and do I need to pay for it?
|
||||
|
||||
iDRAC stands for **Integrated Dell Remote Access Controller**. Ignore the name.
|
||||
Here is what it actually is:
|
||||
|
||||
There is a **second tiny computer built into your server's motherboard**. It has
|
||||
its own processor, its own RAM, its own network port, and it runs 24 hours a day
|
||||
as long as the server has power — even when the server is "off". Dell calls this
|
||||
second computer iDRAC.
|
||||
|
||||
What it lets you do:
|
||||
- See a virtual screen of the server from your web browser (like sitting in front
|
||||
of it with a monitor plugged in, but over the network)
|
||||
- Power the server on and off remotely
|
||||
- Mount a virtual USB drive so you can install an OS without physically being there
|
||||
- Read temperatures, fan speeds, and hardware health
|
||||
- See hardware logs when something fails
|
||||
- Send IPMI commands — which is how our fan control script talks to the fans
|
||||
|
||||
**Do you need to pay for it?** No. The R730xd shipped with **iDRAC8 Enterprise**
|
||||
already built in and fully licensed. You will not be asked to pay for anything.
|
||||
The features are already there.
|
||||
|
||||
The confusion people sometimes have: there is a separate **Proxmox subscription**
|
||||
(about €100/year) which gives you access to their enterprise update servers and
|
||||
commercial support. You do not need this either. We will configure the free
|
||||
community repositories in Phase 6. iDRAC and the Proxmox subscription are
|
||||
completely unrelated things.
|
||||
|
||||
**Summary: pay nothing, skip nothing.**
|
||||
|
||||
---
|
||||
|
||||
### What you need on the table before starting
|
||||
|
||||
- The server plugged into power and a network switch/router
|
||||
- A **separate network cable** for the iDRAC port (the small RJ45 on the back
|
||||
labeled "iDRAC" — it is separate from the four main NIC ports)
|
||||
- A monitor and USB keyboard plugged into the server for the initial setup
|
||||
(after Phase 2 you can do everything from your regular computer over the network)
|
||||
- A USB drive (8 GB or larger) — needed later for the Proxmox installer
|
||||
- Another computer or phone to read this guide
|
||||
|
||||
---
|
||||
|
||||
## Phase 1 — Firmware Updates
|
||||
|
||||
**Why first?** Old firmware has bugs. BIOS from 2016 may not correctly expose
|
||||
the VT-d settings that GPU passthrough requires. The H730 firmware has had fixes
|
||||
for JBOD/non-RAID mode. Updating now prevents chasing ghosts later.
|
||||
|
||||
**Time required:** 30–90 minutes. The server will reboot several times on its own.
|
||||
|
||||
---
|
||||
|
||||
### Step 1.1 — Power on and watch the screen
|
||||
|
||||
Press the power button on the front of the server.
|
||||
|
||||
The screen will show a **Dell splash screen** with the PowerEdge logo. At the
|
||||
bottom of the screen you will see a line of options, something like:
|
||||
|
||||
```
|
||||
F2 = System Setup F10 = Lifecycle Controller F11 = Boot Manager F12 = PXE Boot
|
||||
```
|
||||
|
||||
These options are only available for about **5–8 seconds** before the server
|
||||
continues booting. If you miss the window the server will try to boot an OS
|
||||
(and fail if nothing is installed yet). Just power it off and back on and try again.
|
||||
|
||||
---
|
||||
|
||||
### Step 1.2 — Enter Lifecycle Controller
|
||||
|
||||
Press **F10** when you see the splash screen.
|
||||
|
||||
The screen will go blank for 10–30 seconds, then show the **Lifecycle Controller**
|
||||
loading screen. This is a mini operating system built into the server's firmware.
|
||||
It has nothing to do with your server's main OS. Wait for it to finish loading —
|
||||
it can take up to 90 seconds the first time.
|
||||
|
||||
When it finishes you will see the **Lifecycle Controller Home** screen with a menu
|
||||
on the left side:
|
||||
|
||||
```
|
||||
Home
|
||||
Firmware Update
|
||||
OS Deployment
|
||||
RAID Configuration
|
||||
Hardware Configuration
|
||||
Settings
|
||||
```
|
||||
|
||||
If it asks you to complete initial setup (language, network), do that first —
|
||||
use Tab and arrow keys to navigate, Enter to confirm.
|
||||
|
||||
---
|
||||
|
||||
### Step 1.3 — Go to Firmware Update
|
||||
|
||||
Click or arrow-key to **Firmware Update** on the left menu, then press Enter.
|
||||
|
||||
You will see:
|
||||
|
||||
```
|
||||
Launch Firmware Update
|
||||
```
|
||||
|
||||
Press Enter on that.
|
||||
|
||||
---
|
||||
|
||||
### Step 1.4 — Choose your update method
|
||||
|
||||
You will be asked how you want to get the firmware. You have two options:
|
||||
|
||||
#### Option A — Server has internet access (easiest)
|
||||
|
||||
If your network cable is plugged in and the server can reach the internet:
|
||||
|
||||
1. Select **HTTPS** (it will say something like "downloads.dell.com")
|
||||
2. Press **Next**
|
||||
3. Lifecycle Controller will connect to Dell's servers and **automatically scan
|
||||
your server** to find what firmware versions are installed vs. what is available
|
||||
4. This takes 2–5 minutes — the screen will show a progress bar
|
||||
5. Skip to Step 1.5
|
||||
|
||||
#### Option B — No internet on the server
|
||||
|
||||
You need to download the firmware files on another computer first.
|
||||
|
||||
1. On your other computer, open a browser and go to:
|
||||
**https://www.dell.com/support/home**
|
||||
|
||||
2. You need your server's **Service Tag** — it is a 7-character code. Find it:
|
||||
- On the **front of the server**: there is a small pull-out plastic tab (like a
|
||||
credit card slot) on the left side of the front panel. Pull it out — the
|
||||
Service Tag is printed on it.
|
||||
- Or: on a sticker on the **top** of the server chassis.
|
||||
- Or: it was displayed briefly during POST on the splash screen.
|
||||
|
||||
3. On the Dell support page, click **"View products"** or type the Service Tag
|
||||
into the search bar at the top. Select your server from the results.
|
||||
|
||||
4. Click **"Drivers & Downloads"**
|
||||
|
||||
5. You will see a filter panel. Under **"Category"**, select each of these one
|
||||
at a time and download the latest version:
|
||||
- **iDRAC** — look for "iDRAC8 firmware" — file will end in `.exe` or `.d9`
|
||||
- **BIOS** — look for "BIOS" — file ends in `.exe`
|
||||
- **RAID** — look for "PERC H730" — file ends in `.exe`
|
||||
|
||||
6. Copy all downloaded files onto a **FAT32-formatted USB drive**
|
||||
|
||||
7. Plug the USB drive into the server
|
||||
|
||||
8. In Lifecycle Controller: select **Local Drive (USB)** and press Next
|
||||
|
||||
9. Navigate to the USB drive and select the firmware files
|
||||
|
||||
---
|
||||
|
||||
### Step 1.5 — Review and apply updates
|
||||
|
||||
Lifecycle Controller shows a table of all components with columns like:
|
||||
|
||||
```
|
||||
Component Current Version Available Version Select
|
||||
--------- --------------- ----------------- ------
|
||||
iDRAC8 2.40.40.40 2.85.85.85 [ ]
|
||||
BIOS 1.2.10 2.14.0 [ ]
|
||||
PERC H730 Mini 25.4.0.0018 25.5.9.0001 [ ]
|
||||
```
|
||||
|
||||
1. Check the box next to **every component** that shows a newer Available Version
|
||||
(you can usually click "Select All")
|
||||
2. Click **Install and Reboot** (or **Apply**)
|
||||
3. A warning will say the server will reboot — click **Yes**
|
||||
|
||||
The server will now:
|
||||
- Apply each firmware update
|
||||
- Reboot automatically between some updates
|
||||
- Return to the Lifecycle Controller when finished
|
||||
|
||||
**Do not power off the server during this process.** Just wait. It can take
|
||||
30–60 minutes if there are many updates. The screen will show progress.
|
||||
|
||||
---
|
||||
|
||||
### Step 1.6 — Confirm completion
|
||||
|
||||
When all updates are done, Lifecycle Controller returns to its home screen.
|
||||
You may see a success summary screen first — click **OK** or **Finish**.
|
||||
|
||||
To verify everything worked:
|
||||
1. In Lifecycle Controller, go to **Firmware Update** → **Launch Firmware Update**
|
||||
again
|
||||
2. Run the check one more time
|
||||
3. The Available Version column should now match Current Version for everything
|
||||
you updated (or show no newer version)
|
||||
|
||||
Press **Exit** (or **Finish**) to leave Lifecycle Controller. The server will
|
||||
reboot normally.
|
||||
|
||||
---
|
||||
|
||||
## Phase 2 — iDRAC Setup
|
||||
|
||||
You need to do two things with iDRAC:
|
||||
1. Give it a **static IP address** so it is always reachable at the same address
|
||||
2. Enable **IPMI over LAN** so the fan control script can send commands to it
|
||||
|
||||
There are two ways to do this — through the server's BIOS-like setup (F2),
|
||||
or through the iDRAC web UI once you find its current IP. We will use F2 first
|
||||
to set a static IP, then use the web UI for the rest.
|
||||
|
||||
---
|
||||
|
||||
### Step 2.1 — Enter System Setup (F2)
|
||||
|
||||
Power on (or reboot) the server.
|
||||
|
||||
When the Dell splash screen appears, press **F2**.
|
||||
|
||||
The screen will go blank briefly, then show the **System Setup Main Menu**:
|
||||
|
||||
```
|
||||
System Setup Main Menu
|
||||
|
||||
System BIOS
|
||||
iDRAC Settings
|
||||
Device Settings
|
||||
Service Tag Settings
|
||||
```
|
||||
|
||||
Use the **arrow keys** to highlight **iDRAC Settings** and press **Enter**.
|
||||
|
||||
---
|
||||
|
||||
### Step 2.2 — Set a static IP for iDRAC
|
||||
|
||||
Inside iDRAC Settings you will see another menu:
|
||||
|
||||
```
|
||||
iDRAC Settings
|
||||
|
||||
Network
|
||||
User Configuration
|
||||
Smart Card
|
||||
Update and Rollback
|
||||
...
|
||||
```
|
||||
|
||||
Arrow down to **Network** and press **Enter**.
|
||||
|
||||
The Network screen has several sections. You are looking for the **IPv4 Settings**
|
||||
section. Use Tab or arrow keys to navigate to these fields:
|
||||
|
||||
| Field | What to set |
|
||||
|-------|-------------|
|
||||
| Enable NIC | **Enabled** |
|
||||
| NIC Selection | **Dedicated** (this uses the dedicated iDRAC port on the back) |
|
||||
| Enable IPv4 | **Enabled** |
|
||||
| Enable DHCP | **Disabled** ← change this |
|
||||
| Static IP Address | e.g. `192.168.1.5` (pick an IP outside your router's DHCP range) |
|
||||
| Static Gateway | your router's IP, e.g. `192.168.1.1` |
|
||||
| Static Subnet Mask | `255.255.255.0` |
|
||||
| DNS Server 1 | your router's IP, e.g. `192.168.1.1` |
|
||||
|
||||
> **What IP to use?** Log into your router and find its DHCP range — for example
|
||||
> if DHCP hands out `192.168.1.100` to `192.168.1.200`, pick something outside
|
||||
> that range like `192.168.1.5`. Write this IP down — you will use it often.
|
||||
|
||||
When done, press **Back** or navigate to the bottom and click **Apply**, then **OK**.
|
||||
|
||||
---
|
||||
|
||||
### Step 2.3 — Enable IPMI over LAN
|
||||
|
||||
Still inside iDRAC Settings → Network.
|
||||
|
||||
Scroll down past the IPv4 section until you see **IPMI Settings**.
|
||||
|
||||
Find:
|
||||
|
||||
```
|
||||
Enable IPMI over LAN: [ Disabled ]
|
||||
```
|
||||
|
||||
Change this to **Enabled**.
|
||||
|
||||
This is the setting that allows `ipmitool` commands (used by the fan control
|
||||
script) to reach iDRAC over the network.
|
||||
|
||||
Click **Apply** at the bottom, then **OK** when asked to confirm.
|
||||
|
||||
---
|
||||
|
||||
### Step 2.4 — Change the default password
|
||||
|
||||
Go back to the iDRAC Settings main menu (press **Back**).
|
||||
|
||||
Arrow down to **User Configuration** and press **Enter**.
|
||||
|
||||
You will see a list of user slots. **User 1** is the built-in `root` account.
|
||||
Select it (press Enter).
|
||||
|
||||
> **Why change it?** The factory default password is `calvin`. This is printed
|
||||
> in Dell's public documentation and is widely known. Any device on your network
|
||||
> could log into your iDRAC if you leave it as-is.
|
||||
|
||||
Change:
|
||||
- **User Name:** leave as `root`
|
||||
- **Change Password:** set to **Enabled**
|
||||
- **Password:** enter a strong password
|
||||
- **Confirm Password:** enter it again
|
||||
|
||||
Click **Apply**, then **OK**.
|
||||
|
||||
Press **Finish** to exit iDRAC Settings and return to the System Setup Main Menu.
|
||||
|
||||
**Do not reboot yet** — you still have BIOS settings to configure in Phase 3.
|
||||
|
||||
---
|
||||
|
||||
### Step 2.5 — Verify iDRAC from your browser (do after Phase 3)
|
||||
|
||||
After you finish Phase 3 and let the server reboot, test iDRAC from your other
|
||||
computer:
|
||||
|
||||
1. Make sure the **dedicated iDRAC network port** (small RJ45 labeled "iDRAC" on
|
||||
the server's back panel) is plugged into your switch or router
|
||||
2. Open a browser on your other computer
|
||||
3. Go to: `https://192.168.1.5` (whatever static IP you set in Step 2.2)
|
||||
4. You will see a **certificate warning** — this is normal, iDRAC uses a
|
||||
self-signed certificate. Click **Advanced** → **Proceed anyway** (wording
|
||||
varies by browser)
|
||||
5. The iDRAC8 login page appears — a dark Dell-branded page
|
||||
6. Log in: Username `root`, Password (the one you set in Step 2.4)
|
||||
|
||||
You should see the iDRAC dashboard showing system health, temperatures, and fans.
|
||||
This is your remote window into the server — you can now manage it from your desk.
|
||||
|
||||
---
|
||||
|
||||
## Phase 3 — BIOS Settings
|
||||
|
||||
These settings enable the CPU features that allow devices (GPUs, USB controllers)
|
||||
to be handed directly to virtual machines. **Every setting below is required.**
|
||||
Skipping VT-d is the single most common reason GPU passthrough silently fails.
|
||||
|
||||
You are still in System Setup from Phase 2 (or press F2 again on reboot).
|
||||
|
||||
---
|
||||
|
||||
### Step 3.1 — System BIOS → Processor Settings
|
||||
|
||||
From the System Setup Main Menu, arrow to **System BIOS** and press Enter.
|
||||
|
||||
You will see the System BIOS Settings menu:
|
||||
|
||||
```
|
||||
System BIOS Settings
|
||||
|
||||
System Information
|
||||
Memory Settings
|
||||
Processor Settings ← go here
|
||||
SATA Settings
|
||||
Boot Settings
|
||||
Integrated Devices
|
||||
Serial Communication
|
||||
System Profile Settings
|
||||
Power Management
|
||||
Security
|
||||
Miscellaneous Settings
|
||||
```
|
||||
|
||||
Arrow to **Processor Settings** and press **Enter**.
|
||||
|
||||
Find and set these two options:
|
||||
|
||||
---
|
||||
|
||||
**Virtualization Technology**
|
||||
|
||||
This enables the CPU to run virtual machines efficiently. Without it Proxmox
|
||||
still works but performance is worse.
|
||||
|
||||
```
|
||||
Virtualization Technology: [ Disabled ]
|
||||
↓ change to
|
||||
Virtualization Technology: [ Enabled ]
|
||||
```
|
||||
|
||||
Use the arrow keys or spacebar to toggle the value.
|
||||
|
||||
---
|
||||
|
||||
**VT for Direct I/O** (also shown as "Virtualization Technology for Directed I/O")
|
||||
|
||||
This is the critical one. It enables **IOMMU** — the hardware feature that lets
|
||||
the CPU safely hand a real PCIe device (like your GPU) directly to a virtual
|
||||
machine. Without this, passthrough is impossible.
|
||||
|
||||
```
|
||||
VT for Direct I/O: [ Disabled ]
|
||||
↓ change to
|
||||
VT for Direct I/O: [ Enabled ]
|
||||
```
|
||||
|
||||
Click **Back** to return to System BIOS Settings.
|
||||
|
||||
---
|
||||
|
||||
### Step 3.2 — System BIOS → Integrated Devices
|
||||
|
||||
From the System BIOS Settings menu, arrow to **Integrated Devices** and press Enter.
|
||||
|
||||
Find:
|
||||
|
||||
**SR-IOV Global Enable**
|
||||
|
||||
SR-IOV is a PCIe feature that allows a single physical device to appear as
|
||||
multiple devices. Even though the Quadro P2200 does not use SR-IOV, enabling
|
||||
this globally avoids a class of IOMMU grouping problems.
|
||||
|
||||
```
|
||||
SR-IOV Global Enable: [ Disabled ]
|
||||
↓ change to
|
||||
SR-IOV Global Enable: [ Enabled ]
|
||||
```
|
||||
|
||||
Click **Back**.
|
||||
|
||||
---
|
||||
|
||||
### Step 3.3 — System BIOS → Boot Settings
|
||||
|
||||
From System BIOS Settings, arrow to **Boot Settings** and press Enter.
|
||||
|
||||
You will see:
|
||||
|
||||
```
|
||||
Boot Settings
|
||||
|
||||
Boot Mode: [ BIOS ] ← must change this
|
||||
Boot Sequence
|
||||
...
|
||||
```
|
||||
|
||||
**Boot Mode** — change from BIOS to UEFI:
|
||||
|
||||
```
|
||||
Boot Mode: [ BIOS ]
|
||||
↓ change to
|
||||
Boot Mode: [ UEFI ]
|
||||
```
|
||||
|
||||
> **Why UEFI?** Proxmox uses a tool called `proxmox-boot-tool` to manage the
|
||||
> kernel boot parameters (including the IOMMU settings the GPU passthrough script
|
||||
> writes). This tool only works with UEFI boot. If the server is in Legacy/BIOS
|
||||
> mode the passthrough script will fail and you will have to reinstall.
|
||||
|
||||
A warning may appear saying the boot sequence will be cleared — click **Yes** or
|
||||
**OK**. That is fine since we haven't installed anything yet.
|
||||
|
||||
Click **Back**.
|
||||
|
||||
---
|
||||
|
||||
### Step 3.4 — System BIOS → Power Management
|
||||
|
||||
From System BIOS Settings, arrow to **Power Management** and press Enter.
|
||||
|
||||
Find:
|
||||
|
||||
**Hard Disk Drive Sequencing** — this is the built-in stagger that fires at
|
||||
power-on before the OS loads. It staggers when each drive spins up so they do
|
||||
not all surge at the same time and overload the PSU.
|
||||
|
||||
```
|
||||
Hard Disk Drive Sequencing: [ Disabled ]
|
||||
↓ change to
|
||||
Hard Disk Drive Sequencing: [ Enabled ]
|
||||
```
|
||||
|
||||
Also check:
|
||||
|
||||
**C States** — these are CPU power-saving sleep states. They can add latency
|
||||
to VM workloads. Optional but worth setting for a server:
|
||||
|
||||
```
|
||||
C States: [ Enabled ]
|
||||
↓ change to
|
||||
C States: [ Disabled ]
|
||||
```
|
||||
|
||||
Click **Back**.
|
||||
|
||||
---
|
||||
|
||||
### Step 3.5 — Apply and exit
|
||||
|
||||
From System BIOS Settings, click **Finish** (at the bottom of the menu, you may
|
||||
need to scroll).
|
||||
|
||||
A dialog will appear:
|
||||
|
||||
```
|
||||
Confirm changes and exit?
|
||||
[ Yes ] [ No ]
|
||||
```
|
||||
|
||||
Click **Yes**.
|
||||
|
||||
The server will reboot.
|
||||
|
||||
---
|
||||
|
||||
### Step 3.6 — Confirm the settings took
|
||||
|
||||
After the reboot, press **F2** again to re-enter System Setup and spot-check:
|
||||
|
||||
- **Processor Settings:** VT and VT for Direct I/O should both show **Enabled**
|
||||
- **Boot Settings:** Boot Mode should show **UEFI**
|
||||
|
||||
If either shows Disabled, set it again and apply. Some BIOS versions have a bug
|
||||
where the first Apply does not persist — applying a second time fixes it.
|
||||
|
||||
---
|
||||
|
||||
### Phase 3 complete — what you have now
|
||||
|
||||
| Setting | Why it matters |
|
||||
|---------|---------------|
|
||||
| VT-x (Virtualization Technology) | Lets the CPU run VMs at near-native speed |
|
||||
| VT-d (Direct I/O) | Enables IOMMU — the foundation of all device passthrough |
|
||||
| SR-IOV | Prevents IOMMU group problems with PCIe devices |
|
||||
| UEFI boot mode | Required for Proxmox's boot management and EFI GPU passthrough |
|
||||
| HDD sequencing | Staggers drive spin-up at power-on to protect the PSU |
|
||||
|
||||
**Next:** Phase 4 — Configure the H730 RAID controller to mirror the two
|
||||
2.5" OS drives, then leave the 3.5" drives alone for Proxmox to manage.
|
||||
That walkthrough is in `docs/walkthrough-phases-4-6.md` (coming next).
|
||||