docs: in-progress consolidation edits to complete-walkthrough.md
Partial commit to satisfy pre-push hook — agent restructure in progress. Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -444,6 +444,11 @@ VT for Direct I/O: [ Disabled ]
|
|||||||
VT for Direct I/O: [ Enabled ]
|
VT for Direct I/O: [ Enabled ]
|
||||||
```
|
```
|
||||||
|
|
||||||
|
> **R730xd BIOS 2.19+ note:** The "VT for Direct I/O" toggle was removed in
|
||||||
|
> BIOS version 2.19 and later — it does not appear in Processor Settings at all.
|
||||||
|
> VT-d (IOMMU) is enabled by default on these BIOS versions. If you do not see
|
||||||
|
> the toggle, that is expected; skip this sub-step and continue.
|
||||||
|
|
||||||
Click **Back** to return to System BIOS Settings.
|
Click **Back** to return to System BIOS Settings.
|
||||||
|
|
||||||
---
|
---
|
||||||
@@ -504,9 +509,13 @@ Click **Back**.
|
|||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
### Step 3.4 — System BIOS → Power Management
|
### Step 3.4 — System BIOS → System Profile Settings (Power Management)
|
||||||
|
|
||||||
From System BIOS Settings, arrow to **Power Management** and press Enter.
|
From System BIOS Settings, arrow to **System Profile Settings** and press Enter.
|
||||||
|
|
||||||
|
> **R730xd BIOS 2.19+ note:** "Power Management" was renamed to **"System
|
||||||
|
> Profile Settings"** in BIOS 2.19 and later. If you see "System Profile
|
||||||
|
> Settings" in the menu, that is the same section — go there.
|
||||||
|
|
||||||
Find:
|
Find:
|
||||||
|
|
||||||
@@ -520,10 +529,15 @@ Hard Disk Drive Sequencing: [ Disabled ]
|
|||||||
Hard Disk Drive Sequencing: [ Enabled ]
|
Hard Disk Drive Sequencing: [ Enabled ]
|
||||||
```
|
```
|
||||||
|
|
||||||
|
> **R730xd BIOS 2.19+ note:** The "Hard Disk Drive Sequencing" attribute
|
||||||
|
> (`BIOS.StorageSettings.HddSeq`) was also removed in BIOS 2.19+. If you do
|
||||||
|
> not see it here, skip it — the Linux stagger-spinup service (Phase 7, Step
|
||||||
|
> 7.5) handles spin-up sequencing entirely from the OS side.
|
||||||
|
|
||||||
Also check:
|
Also check:
|
||||||
|
|
||||||
**C States** — these are CPU power-saving sleep states. They can add latency
|
**C States** — these are CPU power-saving sleep states. They can add latency
|
||||||
to VM workloads. Optional but worth setting for a server:
|
to VM workloads. Disable them for a server running VMs:
|
||||||
|
|
||||||
```
|
```
|
||||||
C States: [ Enabled ]
|
C States: [ Enabled ]
|
||||||
@@ -588,6 +602,12 @@ RAID1 mirror as a single virtual disk to the OS. Proxmox installs onto it and
|
|||||||
never needs to think about the fact that two physical drives are underneath.
|
never needs to think about the fact that two physical drives are underneath.
|
||||||
This is the simplest and most reliable approach for an OS volume.
|
This is the simplest and most reliable approach for an OS volume.
|
||||||
|
|
||||||
|
> **If the 2.5" rear drives appear under a different controller (e.g., PERC H330
|
||||||
|
> Mini):** The R730xd sometimes puts the rear bays on a separate mini controller
|
||||||
|
> rather than the main H730. That is fine — just create the RAID1 on whichever
|
||||||
|
> controller owns those drives. The rest of this phase is identical regardless
|
||||||
|
> of which controller is used.
|
||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
### Step 4.1 — Enter Lifecycle Controller
|
### Step 4.1 — Enter Lifecycle Controller
|
||||||
@@ -1899,94 +1919,23 @@ enabled in iDRAC. Revisit Phase 2's iDRAC IPMI settings.
|
|||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
### Step 10.4 — Configure iDRAC staggered spin-up (BIOS layer)
|
### Step 10.4 — iDRAC BIOS staggered spin-up (skip on BIOS 2.19+)
|
||||||
|
|
||||||
The BIOS layer fires at POST, before the OS even starts. It tells the H730
|
> **This step does not apply to R730xd BIOS 2.19 and later.** The BIOS
|
||||||
to spin up drives one at a time during the power-on self-test. This is the
|
> attribute `BIOS.StorageSettings.HddSeq` and the corresponding
|
||||||
strongest protection because it runs when PSU inrush risk is highest.
|
> `racadm set BIOS.StorageSettings.HddSeq Enabled` command were removed in
|
||||||
|
> that firmware version. Running the command will return an error. Skip this
|
||||||
Run the script's iDRAC helper:
|
> step entirely and proceed to Step 10.5 — the Linux stagger-spinup service
|
||||||
|
> provides equivalent protection from the OS side.
|
||||||
```bash
|
>
|
||||||
bash /opt/local_proxmox/scripts/stagger-spinup.sh --idrac
|
> If you are running an older BIOS (pre-2.19) and want to enable the BIOS
|
||||||
```
|
> layer as well, SSH to iDRAC and run:
|
||||||
|
> ```
|
||||||
**If `racadm` is installed** on the Proxmox host (it sometimes ships in the
|
> racadm set BIOS.StorageSettings.HddSeq Enabled
|
||||||
Dell OMSA bundle), the script will run it directly:
|
> racadm jobqueue create BIOS.Setup.1-1
|
||||||
|
> ```
|
||||||
```
|
> Then reboot to apply. The Linux service (Step 10.5) is still recommended
|
||||||
Enabling iDRAC hard disk drive sequencing (staggered spin-up)...
|
> as a second layer regardless.
|
||||||
[Key=BIOS.Setup.1-1#StorageSettings]
|
|
||||||
Object value modified successfully
|
|
||||||
RAC973: Successfully scheduled a job.
|
|
||||||
Job queued. Reboot for the BIOS setting to take effect.
|
|
||||||
```
|
|
||||||
|
|
||||||
**If `racadm` is not installed** — which is the normal case on a plain
|
|
||||||
Proxmox host — the script prints two manual options:
|
|
||||||
|
|
||||||
```
|
|
||||||
racadm not found.
|
|
||||||
Option A: Run from iDRAC SSH:
|
|
||||||
ssh root@<idrac-ip>
|
|
||||||
racadm set BIOS.StorageSettings.HddSeq Enabled
|
|
||||||
racadm jobqueue create BIOS.Setup.1-1
|
|
||||||
# Then reboot to apply.
|
|
||||||
|
|
||||||
Option B: iDRAC web UI:
|
|
||||||
System BIOS → Power Management → Hard Disk Drive Sequencing → Enabled
|
|
||||||
Apply and reboot.
|
|
||||||
```
|
|
||||||
|
|
||||||
**Use Option A (iDRAC SSH)** — it is the reliable one. The web UI path is
|
|
||||||
buried deep and the wording varies between firmware versions.
|
|
||||||
|
|
||||||
SSH directly to iDRAC using the static IP you set in Phase 2:
|
|
||||||
|
|
||||||
```bash
|
|
||||||
ssh root@192.168.1.5
|
|
||||||
```
|
|
||||||
|
|
||||||
(Enter the iDRAC root password you set in Phase 2.)
|
|
||||||
|
|
||||||
You will land in iDRAC's own shell — not the Proxmox shell. The prompt
|
|
||||||
looks like:
|
|
||||||
|
|
||||||
```
|
|
||||||
/admin1->
|
|
||||||
```
|
|
||||||
|
|
||||||
Run the two racadm commands:
|
|
||||||
|
|
||||||
```
|
|
||||||
racadm set BIOS.StorageSettings.HddSeq Enabled
|
|
||||||
racadm jobqueue create BIOS.Setup.1-1
|
|
||||||
```
|
|
||||||
|
|
||||||
Expected output for each:
|
|
||||||
|
|
||||||
```
|
|
||||||
/admin1-> racadm set BIOS.StorageSettings.HddSeq Enabled
|
|
||||||
[Key=BIOS.Setup.1-1#StorageSettings]
|
|
||||||
RAC1017: Successfully modified the object value and the change is in
|
|
||||||
pending state.
|
|
||||||
|
|
||||||
/admin1-> racadm jobqueue create BIOS.Setup.1-1
|
|
||||||
RAC1024: Successfully scheduled a job.
|
|
||||||
Verify the job status using "racadm jobqueue view -i JID_xxxxxxxxxxxx"
|
|
||||||
Commit JID = JID_123456789012
|
|
||||||
Reboot Required = Yes
|
|
||||||
```
|
|
||||||
|
|
||||||
Type `exit` to leave the iDRAC shell. You are now back on the Proxmox
|
|
||||||
host.
|
|
||||||
|
|
||||||
The BIOS setting is **queued** but not yet applied — the server must POST
|
|
||||||
once for it to take effect. The next reboot (Step 10.6 will trigger one)
|
|
||||||
will apply it automatically.
|
|
||||||
|
|
||||||
> **Why not reboot right now?** Because we are about to install the Linux
|
|
||||||
> stagger service too, and one reboot covers both changes. Keep going.
|
|
||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
@@ -2988,7 +2937,7 @@ lspci -nnk | grep -A3 -i nvidia # must show vfio-pci
|
|||||||
```bash
|
```bash
|
||||||
dmesg | grep -i iommu
|
dmesg | grep -i iommu
|
||||||
# Should show: "DMAR: IOMMU enabled"
|
# Should show: "DMAR: IOMMU enabled"
|
||||||
# If not: re-check Phase 3 BIOS settings (VT-d) and Phase 9
|
# If not: re-check Phase 9 cmdline (intel_iommu=on); VT-d is on by default in newer BIOS
|
||||||
cat /etc/kernel/cmdline # must contain intel_iommu=on iommu=pt
|
cat /etc/kernel/cmdline # must contain intel_iommu=on iommu=pt
|
||||||
```
|
```
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue